Tubelite aluminum storefront and curtain wall on a commercial facade
Tubelite architectural aluminum

Tubelite Aluminum Framing for Storefront, Curtain Wall & Thermal Entrances

Specify extruded aluminum entrances, stick-built curtain wall, and thermally broken windows that meet AAMA air-water-structural protocols, NFRC thermal ratings, and Miami-Dade coastal wind criteria for commercial and institutional projects.

Get Specifications
Performance reference

System Specs Architects & Spec Writers Verify First

Expand each family when comparing Tubelite storefront doors, curtain wall spans, and thermal entrances against project manuals that cite U-factor, SHGC, design wind pressure, and hardware schedules.

Typical sightline1-3/4″ to 2″ face widths for retail and lobby storefront
Glazing pocket1″ insulating glass assemblies with captured or structural silicone options
Air / waterAAMA 501 laboratory protocols for air infiltration and water penetration
Hardware pathPivots, closers, weatherstrip, and panic devices coordinated to door leaf weight

System typeStick-built aluminum curtain wall with pressure-equalized rainscreen logic
Mullion depthSelected to span floor-to-floor heights and design wind pressure
Thermal pathThermal breaks sized for NFRC whole-system U-factor targets
Coastal noteMiami-Dade NOA pathways available where jurisdiction requires impact glazing

Thermal doorsThermally broken entrance leaves for climate-zone energy codes
Window assembliesProjected, casement, and fixed aluminum units matching storefront aesthetics
Finish optionsClass I / II anodize and 70% PVDF coatings per AAMA finish specifications
Color referenceTubelite color chart samples for architect finish boards and mock-ups
Aluminum curtain wall mullion detail with thermal break
Engineering advantages

Why Specification Writers Choose Tubelite Aluminum

  • 01

    AAMA & NFRC documented performance

    Air permeability, water penetration, structural load bearing capacity, and thermal bridging data packaged so inspectors and energy modelers can verify claims against project specs.

  • 02

    Hardware & weatherstrip coordination

    Door pivots, closers, weatherstrip, and panic hardware selected as a system—not as mismatched aftermarket parts.

  • 03

    Coastal & high-wind pathways

    Miami-Dade NOA-approved assemblies support jurisdictions that require impact resistance ratings and elevated wind load (PSF) design pressures.

  • 04

    LEED-aligned component documentation

    Recycled content and finish VOC notes help sustainability consultants complete credit worksheets without rework.

  • 05

    Shop-drawing discipline since 1945

    Eight decades of aluminum fenestration manufacturing keep elevation details aligned with field installation sequences.

Compliance evidence

Credentials Structural Engineers Request on Submittals

  • AAMA 501 badge

    AAMA 501

    Laboratory air, water, and structural protocols that mirror how architects write storefront and curtain wall performance sections.

  • NFRC Rated badge

    NFRC Rated

    Whole-product U-factor and SHGC values for energy code compliance and envelope modeling on commercial projects.

  • Miami-Dade NOA badge

    Miami-Dade NOA Approved

    Impact and high-velocity hurricane zone pathways for coastal elevations that cannot rely on generic inland ratings.

  • LEED components badge

    LEED Certified Components

    Documentation support for material credits when aluminum framing contributes to project sustainability scorecards.

Markets served

Building Types That Specify Tubelite Framing

Scroll the row to match your project typology—each card reflects aluminum fenestration scenarios, not generic construction slogans.

Retail storefront aluminum entrance

Retail & mixed-use

High-cycle entrances, narrow sightlines, and finish continuity along street-facing storefronts.

Healthcare building curtain wall

Healthcare campuses

Accessible entrances, infection-control glazing details, and durable anodized finishes for high traffic.

University building aluminum windows

Education & civic

Thermal comfort targets, security hardware packages, and long-span curtain wall for atriums.

Hospitality hotel aluminum facade

Hospitality

Lobby monumental doors, PVDF color matching, and acoustic flanking control at guest corridors.

Office tower curtain wall elevation

Commercial office

Floor-to-floor stick curtain wall, operable vents, and NFRC data for tenant energy models.

Coastal building impact glazing

Coastal & high-wind

Miami-Dade pathways, design pressure schedules, and hardware that survives hurricane protocols.

Field feedback

What Project Teams Report After Install

“The shop drawings flagged our hardware schedule conflicts before fabrication. Storefront leaf weights and closer sizes finally matched on the first delivery.”


Project manager avatar
Marcus Ellison Project Manager, Midwest GC

“NFRC values lined up with our energy model, and the thermal break documentation cut two rounds of RFI noise on the envelope package.”


Specification writer avatar
Priya Nandakumar Specification Writer, A/E Firm

“Coastal NOA paperwork arrived with the submittal set—inspectors did not bounce us for missing impact pathway notes on the lobby curtain wall.”


Facade consultant avatar
Diego Alvarez Facade Consultant, Coastal Projects
Next step

Request Technical Data for Your Elevation Package

Share building type, design wind pressure, U-factor targets, and finish selections. Tubelite engineers return system recommendations, hardware notes, and catalog references suited to your jurisdiction.

  • Storefront, curtain wall, or thermal entrance selection guidance
  • Color chart and finish sample coordination
  • Installation sequence notes for field crews
  • Miami-Dade / high-wind pathway screening